Parameters for Life po4 8S BMS | ||||||||
Discription | Specification | Unite | Remark | |||||
80A | 100A | 120A | 150A | 200A | ||||
Discharge | Contine discharge current | 80 | 100 | 120 | 150 | 200 | A | |
Discharge Peak current | 220 | 220 | 530 | 530 | 530 | A | ||
Over current protection | 220 | 220 | 530 | 530 | 530 | A | ||
Charge | Charge Voltage | 28.8 | V | |||||
Charge current | 80 | 100 | 120 | 150 | 200 | A | Charge in separate port set as required | |
Over charge protection | Over charge detect voltage | 3.65±0.025 | V | |||||
Over charge protection delay | 0.5 | S | ||||||
Over charge release voltage | 3.6±0.05 | V | ||||||
Balance | Balance detect voltage | 3.6 | V | |||||
Balance release voltage | 3.6 | V | ||||||
Balance current | 35±5 | mA | Balance current35±5mA | |||||
Over discharge protection | Over discharge detect voltage | 2.5±0.05 | V | |||||
Over discharge detect delay | 0.5 | S | ||||||
Over discharge release voltage | 3.0±0.05 | V | ||||||
Over current protection | Over current detect voltage | 200 | mV | |||||
Over current detect delay | 9 | MS | ||||||
Over current protection release condition | Off load | |||||||
Short circuit protetion | Short circuit protection condition | Short circuit of external load | ||||||
Short circuit detect delay | 250 | uS | ||||||
Short circuit protection release condition | Off load | |||||||
Temp Protection | Temp Protection | NA | ℃ | Set as required | ||||
Inner resistance | Conductive resistance in main circuit | ≤10 | mΩ | |||||
Electricity self consume | Working current | ≤40 | uA | |||||
Sleeping current(battery in discharge) | ≤20 | uA | ||||||
Work Temp | Temp range | -40 | ℃ |